Fields / Gullfaks Sør / 34/10-53 S
34/10-53 S
Exploration, wildcatPlugged and abandonedGas and condensate
Drilled by Statoil Petroleum AS with Deepsea Atlantic in Gullfaks Sør, 06.12.2010 to 24.03.2011 (108 days), to 4 526,0 m in the Statfjord Group.
Water depth137,0 m
Total depth4 526,0 m MD
Vertical depth3 879,0 m TVD
Bottom-hole temperature140 °C
Max inclination56,0°
Rotary table32,0 m
Formation at total depthStatfjord Group
RigDeepsea Atlantic
Spud06.12.2010
Completed24.03.2011
OperatorStatoil Petroleum AS
Position61,0680 N, 2,1168 E
Formations
20 tops reported, measured depth in metres.
Temperature
| Reported at total depth | 140 °C |
| Gullfaks Sør gradient | 36,5 °C/km |
| Estimated at total depth from the gradient | 139 °C |
The gradient is the median of 24 released wells in Gullfaks Sør with a reported bottom-hole temperature, counted from 4 °C at the sea floor.
Offset wells
The nearest wellbores within 15 km, straight-line distance at the surface.
| Wellbore | km | Total depth, m | BHT | Mud max, g/cm³ | Year |
|---|---|---|---|---|---|
| 34/10-53 A same well | 0,0 | 4 855,0 | - | 1,58 | 2011 |
| 34/10-U-16 | 0,6 | 600,0 | - | - | 2015 |
| 34/10-Q-4 H | 0,6 | 4 529,0 | - | - | 2015 |
| 34/10-Q-1 H | 0,6 | 4 309,0 | - | - | 2015 |
| 34/10-Q-3 H | 0,6 | 4 361,0 | - | - | 2019 |
| 34/10-Q-2 AH | 0,6 | 5 882,0 | - | - | 2022 |
| 34/10-Q-2 H | 0,6 | 5 827,0 | - | - | 2019 |
| 34/10-H-4 AH | 2,7 | 5 857,0 | - | - | 2013 |
Casing and formation tests
The casing programme as reported, shallowest first. The test is the leak-off (LOT) or formation integrity (FIT) result as an equivalent mud density.
| String | Casing | Shoe, m | Hole | Hole depth, m | Test, g/cm³ |
|---|---|---|---|---|---|
| Conductor | 30" | 239,0 | 36" | 242,0 | - |
| Surface casing | 20" | 1 059,6 | 26" | 1 068,0 | 1,53 LOT |
| Intermediate | 13 3/8" | 2 249,2 | 17 1/2" | 2 255,0 | 1,74 LOT |
| Intermediate | 9 5/8" | 3 494,0 | 12 1/4" | 3 496,0 | 1,96 LOT |
| Liner | 7" | 4 524,0 | 8 1/2" | 5 426,0 | - |
Mud weight
11 measurements, one dot each, 1,20 to 1,58 g/cm³ against measured depth, glydril, versatec, versatherm.