Fields / 35/11-3 S
35/11-3 S
Exploration, wildcatPlugged and abandonedOil shows
Drilled by Mobil Exploration Norway INC with Dyvi Stena, 27.06.1989 to 09.09.1989 (74 days), to 4 040,0 m in the Statfjord Group.
Water depth358,0 m
Total depth4 040,0 m MD
Vertical depth4 025,0 m TVD
Bottom-hole temperature144 °C
Max inclination9,3°
Rotary table25,0 m
Formation at total depthStatfjord Group
RigDyvi Stena
Spud27.06.1989
Completed09.09.1989
OperatorMobil Exploration Norway INC
Position61,0867 N, 3,3385 E
Formations
32 tops reported, measured depth in metres.
Temperature
| Reported at total depth | 144 °C |
The wellbore is not in a field, so no field gradient applies.
Offset wells
The nearest wellbores within 15 km, straight-line distance at the surface.
| Wellbore | km | Total depth, m | BHT | Mud max, g/cm³ | Year |
|---|
| 35/11-22 S | 0,7 | 3 882,0 | - | 1,52 | 2018 |
| 35/10-U-1 | 2,5 | 1 000,0 | - | - | 2026 |
| 35/10-15 A | 3,2 | 3 309,0 | - | - | 2025 |
| 35/10-15 S | 3,2 | 2 105,0 | - | - | 2025 |
| 35/11-5 | 3,3 | 3 769,0 | 134 °C | 1,51 | 1991 |
| 35/11-24 A | 3,4 | 3 549,0 | 125 °C | 1,37 | 2020 |
| 35/11-24 B | 3,4 | 3 479,0 | 118 °C | 1,37 | 2020 |
| 35/11-24 S | 3,4 | 3 200,0 | 117 °C | 1,37 | 2020 |
Casing and formation tests
The casing programme as reported, shallowest first. The test is the leak-off (LOT) or formation integrity (FIT) result as an equivalent mud density.
| String | Casing | Shoe, m | Hole | Hole depth, m | Test, g/cm³ |
|---|
| Conductor | 30" | 498,0 | 36" | 499,0 | - |
| Intermediate | 20" | 1 000,0 | 26" | 1 013,0 | 1,42 LOT |
| Intermediate | 13 3/8" | 2 040,0 | 17 1/2" | 2 057,0 | 1,70 LOT |
| Intermediate | 9 5/8" | 3 111,0 | 12 1/4" | 3 115,0 | 1,91 LOT |
| Open hole | - | 4 040,0 | 8 1/2" | 4 040,0 | - |
Mud weight
46 measurements, one dot each, 1,00 to 1,62 g/cm³ against measured depth, water based.